How to disassemble and clean the 易彤破壁机不工作维修 smoke
1。Please turn off the power first。
2。Slowly remove the oil cup on the machine in the horizontal direction,Unscrew the oil screen screw,Remove oil sieve,Suspend the nut clockwise,Grab the impeller sleeve and pull it out,You can remove the impeller for cleaning(Pay attention to cleaning the impeller,Do not use wire velvet,Wear rubber gloves cleaning impeller,Prevent impeller from scratch your hand quickly)。
3。After cleaning the impeller,Reinstall the motor shaft, Pay attention to the horizontal pin on the motor shaft。There is a keyway on the impeller,Both must be aligned。Installation,Please note,The impeller bushing and motor shaft are basically flush,Motor shaft is slightly recessed is normal,at this time, Tighten the knot counterclockwise。Apart from this, Screw the loose to tighten the nut with hands lead to high noise and low suction。
A good way to clean the tobacco oil cup
Before using the oil hood,Plastic film in a clean oil cup,Whenever you need to clean the waste oil in the oil cup,Just pull out the movie。
Rumbering hood time adjustment method with clock function
Adjustment method:The first time is booting default12:30,at this time, You can press“ +”with“-”Key to adjust clocks and minutes,Open the clock display after each power failure will be restored to the default12:30。Time adjustment or minute adjustment,You need to press the corresponding button1。5When the second time is displayed,Adjust the time。
How to deal with newly purchased pumping hood bulbs damage
the first, Please check the production time of smoke hood at home,in the case ofCXW-219, 8month18After the day199Series exhaust hood, 2005These two bulbs are randomly provided to users.,Not within the warranty(See the manual:In the second service guarantee2Strip)。We will provide you with spotlights random,It is stored in the attachment screw package。
After purchasing machine,You can install light bulbs themselves,The specific operation is as follows(See the description:how to use):Use a spotlight fixture counterclockwise rotation20°,Unloading spotlight cover card ring,After tightening the lamp clockwise,Then install the lamp cover card ring in the opposite order。
How to disassemble the oil cup of China
Operation method:Please use the correct way to remove oil network,If you grab the oil cup and take it out 易彤破壁机全国维修点 when you remove the oil network, Oil cup will be damaged。Since this oil hood has improved oil network,Improved The number of magnets in the oil network increases,The corresponding suction also increases。User does not follow the correct operation method when the oil network is taken,This is not the quality of the oil cup。See the detailed instructions in the manual to operate correctly。
Contact method for container cover of European suction hood
1。The lampshade of European pumping hood can be dismantled,The specific disassembly method is described in the manual.,Please follow the steps in the manual.。
2。In order to facilitate consumers to disassemble,For use with bulb type European, Side champion Spotlight tools are also specially equipped,Light rotating spotlight tool,The lampshade can be easily unloaded。